Your patients use the term “dental scanner” to refer to two very different tools: the intraoral scanner—an optical camera that replaces the alginate impression—and the CBCT, the 3D radiographic exam you order before an implant. The terminology patients use masks a key question for practitioners: What investment is needed for what purpose? And above all, in which situations is one or the other the best choice?
This guide provides a clear, jargon-free overview of these two technologies: what they actually do, their applications, their limitations, and how to integrate them into a digital workflow.
Intraoral Scanner, CBCT: Three Tools That Should Not Be Confused
In a dental office, three tools coexist and complement one another. The intraoral scanner captures the surface of the teeth and gums using light (often structured light or a laser), without any radiation: it creates a digital impression. The intraoral X-ray sensor, on the other hand, produces standard retroalveolar X-rays in 2D using an X-ray beam. CBCT (cone beam computed tomography) reconstructs a three-dimensional image from X-rays to visualize the bone in depth.
The confusion stems from the word “scanner,” which patients use to refer to all three. A good habit to adopt during a consultation is to rephrase the question: “Are you referring to the optical scan—which uses no radiation—or to the prescribed 3D exam?” This clarification puts patients at ease and prevents many misunderstandings, including those regarding pricing.
The intraoral scanner: optical impressions, radiation-free
The intraoral scanner replaces traditional impressions: the dentist moves a small camera around the mouth and, in just a few minutes, obtains a 3D model of the dental arch. Its uses are well established:
- impressions for dental restorations (crowns, bridges, inlays) sent directly to the lab as digital files;
- Orthodontic study models and aligner follow-up;
- Communication with the patient: Showing the prepared tooth on the screen changes how the treatment plan is explained;
- Restorations scanned in the dental chair, with in-office milling or 3D printing.
Patient acceptance is excellent, even among patients with a phobia of impressions, and optical impressions eliminate the risk of casting errors or material deformation. Our recommendations for making the right choice are based on three simple criteria: capture speed, software compatibility (ability to export to standard formats), and the camera’s ease of use for your assistants.
For more information, our article on the benefits of intraoral scanners for dental practices details the concrete advantages they offer on a day-to-day basis.
CBCT: 3D Radiography, by Prescription
CBCT follows a different approach: it reveals what 2D imaging hides—namely, the three-dimensional structure of the bone. Its standard indications in the dental office or imaging suite are:
- Pre-implant evaluation: bone height, width, and density; position of structures at risk;
- complex endodontics: removal of instrument fragments, non-healing lesions;
- impacted teeth and their relationship to the inferior alveolar nerve prior to surgery;
- Traumatology, fractures, resorption: situations where 2D imaging is no longer sufficient.
It is a radiological procedure in its own right. The exam is ordered by a physician, who must justify the need for it: exposure to X-rays is acceptable only if the information expected to be obtained will influence your treatment decision. In France, this principle of justification and optimization is reiterated bythe Nuclear Safety Authority, which regulates medical imaging and equipment in medical practices.
In practice, not all CBCTs are created equal. The field of view (small field for a single tooth, large field for an entire dental arch) determines the radiation dose and image resolution. The rule is simple: use the smallest field necessary to answer the clinical question, and use pediatric or low-dose protocols when appropriate.
Comparison Chart: Intraoral vs. CBCT
| Intraoral scanner | CBCT | |
|---|---|---|
| Nature | Surface Optical Fingerprint | 3D Radiological Examination |
| Radiation | None | X-rays: Keeping the Dose Under Control |
| Statute of Limitations | No (armchair act) | Yes, with justification |
| What it shows | Crowns, gums, dental arch | Bone volume, deep structures |
| Typical Uses | Dental Prosthetics, Orthodontics, Communication | Implantology, Endodontics, Surgery |
| Cost | Current Firm Investment | Fully equipped practice or radiology center |
The two are not mutually exclusive: the intraoral scanner shows the surface, while the CBCT shows the bone. A comprehensive implant treatment plan utilizes both, at different stages of the treatment process.
Radiation Protection: Your Practical Obligations
As soon as you expose a patient to X-rays, the regulations apply, and compliance is verified during ARS inspections. Here are three key points to keep in mind:
- Justify each imaging study: the clinical question must require this imaging, not merely facilitate it;
- Optimize the settings: narrow field of view, lowest dose compatible with a usable image;
- Inform the patient—especially pregnant women and children—and document the examination in their medical record.
If you order a CBCT but do not have the equipment at your practice, the exam is performed at an approved radiology center: the radiology report is then sent to the prescribing physician. This requirement for interpretation and traceability is detailed in our article on radiology reports.
Integrating both into a digital workflow
The real issue is no longer equipping the practice with individual tools, but rather sharing images between them. The optical scan feeds into the lab, the CBCT feeds into the surgical planning software, and your 2D X-rays feed into your patient follow-up. This is what digital dentistry is transforming on a daily basis: less data entry, more readable records, and seamless communication with the practice’s partners.
When it comes to 2D imaging, tools such as Allisone assist the dentist with every X-ray: the analysis is integrated into the practice’s software, the relevant dental region is identified, and notable findings are flagged, allowing for a visual review in just a few seconds. The dentist remains in control: they validate, interpret, and decide. AI assists the dentist—it never replaces them.
One final point, which is often overlooked: these tools are only as good as the team using them. Train your assistants on the intraoral scanner as soon as the equipment arrives, and make radiation protection a team priority—not just the dentist’s responsibility.
Key Takeaways
- The intraoral scanner is a radiation-free optical impression-taking device designed for prosthetics, orthodontics, and communication;
- CBCT is a prescription-based 3D imaging test indicated when the clinical issue involves bone;
- The two complement each other: surface for one, volume for the other, often within the same treatment plan;
- Radiation protection and justification are not optional: they are essential to your practice's compliance.
Still can't decide between the two for your practice? Tell us about your practice: we'll work with you to identify where digital imaging can save you time without changing your clinical routines. Schedule a demo.
Related articles
All the latest news on the future of dentistry