A patient presents with an implant placed ten years ago, with no medical records and no recollection of the system used. The X-ray is the only reliable source of information: it will allow us to identify the implant system, establish traceability, and ensure the safety of the rest of the treatment. For both individual practitioners and clinic groups, knowing how to identify an implant on an X-ray is both a clinical and an organizational skill. Here is the method, step by step.

Why Identify an Implant on an X-Ray?

Identifying an unknown implant arises in specific and common situations: taking over an incomplete patient record, assisting a colleague, treating a patient who came from another practice, or performing maintenance on an implant placed several years ago. Knowing the brand and model is essential for selecting compatible components (abutment, healing screw, placement key), ordering replacement parts, and ensuring the consistency of the treatment plan.

It is also an increasingly stringent regulatory requirement. The standard on the safety and traceability of implants requires that information regarding implanted devices—including the manufacturer, model, and lot number—be retained. A practice that cannot meet this requirement is taking a documentary and medical risk.

Finally, the issue of the patient's medical record is particularly pressing in clinic networks: when multiple practitioners treat the same patient, the implant must be identified once and for all and made accessible to everyone.

What a 2D X-ray Reveals About an Implant

On an X-ray (retroalveolar, bitewing, or panoramic), an implant can be identified based on four categories of morphological features:

  1. The thread (or pitch): its shape—triangular, trapezoidal, or square—and its pitch—fine or coarse—are often the manufacturer’s signature. A thread with a pointed apex suggests a self-tapping profile, while a more parallel thread suggests a bone-condensation system.
  2. The implant body: apparent diameter, length, taper. The cylindrical or conical shape and the transition between the thread and the neck provide information about the system's geometry.
  3. The implant-abutment connection: external hex, internal hex, Morse taper, switched platform. This is the most distinguishing factor, as each manufacturer has made the connection a key differentiator.
  4. The neck and platform: presence or absence of microgrooves, polishing grooves, neck height, and the shape of the transition between the implant body and the abutment.

This information is then cross-referenced with manufacturers' catalogs: by comparing the X-ray image with known references, it is possible to identify the make and model.

The Step-by-Step Method

  1. Isolate the implant site on the X-ray and assess the image quality: a blurry or poorly angled X-ray makes identification difficult; a centered retroalveolar X-ray is often easier to read than a panoramic X-ray.
  2. Record the morphological characteristics described above: filament, body, connection, and neck. Record them systematically.
  3. Compare with the manufacturers' references: technical data sheets, implant atlases, and manufacturer documentation. This is the most time-consuming step, especially for older systems or those distributed under private labels.
  4. Verify the hypothesis using the part: measure the platform diameter, check that the components are compatible, and record the results in the patient's file.

This manual method is time-consuming and depends on each person's experience. This is precisely where identification tools come into play.

The Limitations of 2D Imaging, and Why CBCT Isn't a Panacea

2D radiography flattens a three-dimensional structure: the overlapping of structures, the angles at which the images are taken, and the projection slightly distort the implant’s outline. A thread may appear denser, and a hexagonal connection may be projected at a misleading angle. These physical limitations make visual identification difficult for certain closely spaced systems.

CBCT provides a volumetric view that is useful for positioning, but it is not the gold standard for implant identification: the distinguishing features (threads, connection) are best visualized on a sharp, centered 2D image. The clinician always retains control: identification is a documented clinical decision, not an automated reading.

AI-Assisted Recognition

Manually identifying implants on 2D images is a use case where AI provides immediate time savings: it analyzes the implant’s morphological features on the X-ray and suggests the most likely compatible systems, which the practitioner then validates.

Spotimplant works on this principle: artificial intelligence-based dental implant recognition analyzes the X-ray and suggests a match in a matter of seconds, drawing from a database of implant systems. The dentist retains the final decision: AI assists the dentist; it does not replace them.

For a practice, the benefit is time savings and documented traceability; for a group of clinics, it is consistency in practices: regardless of which practitioner reviews the X-ray, the recommended course of action is the same, and the medical record is documented in the same way.

Record the information for traceability

Identification is only useful if the information is retained. The implant reference number, manufacturer, lot number, and date of implantation must be included in the patient’s medical record, ideally along with the annotated X-ray image. This is the key to stress-free maintenance and effective management of medical liability.

In Practice: Incorporating Identification into Your Protocol

Whether you’re handling an older case or standardizing practices across a group of clinics, the process is the same: a documented identification protocol, an accessible implant database, and a solution like Spotimplant integrated into the radiographic workflow. If you’d like to see how assisted identification fits into daily practice, request a demo: the Allisone team will show you how it works using your own X-rays.

Blog

Related articles

All the latest news on the future of dentistry

Not yet an Allisone user

Request a demo

Identifying a Dental Implant on an X-Ray: The Method

Published on

A patient presents with an implant placed ten years ago, with no medical records and no recollection of the system used. The X-ray is the only reliable source of information: it will allow us to identify the implant system, establish traceability, and ensure the safety of the rest of the treatment. For both individual practitioners and clinic groups, knowing how to identify an implant on an X-ray is both a clinical and an organizational skill. Here is the method, step by step.

Why Identify an Implant on an X-Ray?

Identifying an unknown implant arises in specific and common situations: taking over an incomplete patient record, assisting a colleague, treating a patient who came from another practice, or performing maintenance on an implant placed several years ago. Knowing the brand and model is essential for selecting compatible components (abutment, healing screw, placement key), ordering replacement parts, and ensuring the consistency of the treatment plan.

It is also an increasingly stringent regulatory requirement. The standard on the safety and traceability of implants requires that information regarding implanted devices—including the manufacturer, model, and lot number—be retained. A practice that cannot meet this requirement is taking a documentary and medical risk.

Finally, the issue of the patient's medical record is particularly pressing in clinic networks: when multiple practitioners treat the same patient, the implant must be identified once and for all and made accessible to everyone.

What a 2D X-ray Reveals About an Implant

On an X-ray (retroalveolar, bitewing, or panoramic), an implant can be identified based on four categories of morphological features:

  1. The thread (or pitch): its shape—triangular, trapezoidal, or square—and its pitch—fine or coarse—are often the manufacturer’s signature. A thread with a pointed apex suggests a self-tapping profile, while a more parallel thread suggests a bone-condensation system.
  2. The implant body: apparent diameter, length, taper. The cylindrical or conical shape and the transition between the thread and the neck provide information about the system's geometry.
  3. The implant-abutment connection: external hex, internal hex, Morse taper, switched platform. This is the most distinguishing factor, as each manufacturer has made the connection a key differentiator.
  4. The neck and platform: presence or absence of microgrooves, polishing grooves, neck height, and the shape of the transition between the implant body and the abutment.

This information is then cross-referenced with manufacturers' catalogs: by comparing the X-ray image with known references, it is possible to identify the make and model.

The Step-by-Step Method

  1. Isolate the implant site on the X-ray and assess the image quality: a blurry or poorly angled X-ray makes identification difficult; a centered retroalveolar X-ray is often easier to read than a panoramic X-ray.
  2. Record the morphological characteristics described above: filament, body, connection, and neck. Record them systematically.
  3. Compare with the manufacturers' references: technical data sheets, implant atlases, and manufacturer documentation. This is the most time-consuming step, especially for older systems or those distributed under private labels.
  4. Verify the hypothesis using the part: measure the platform diameter, check that the components are compatible, and record the results in the patient's file.

This manual method is time-consuming and depends on each person's experience. This is precisely where identification tools come into play.

The Limitations of 2D Imaging, and Why CBCT Isn't a Panacea

2D radiography flattens a three-dimensional structure: the overlapping of structures, the angles at which the images are taken, and the projection slightly distort the implant’s outline. A thread may appear denser, and a hexagonal connection may be projected at a misleading angle. These physical limitations make visual identification difficult for certain closely spaced systems.

CBCT provides a volumetric view that is useful for positioning, but it is not the gold standard for implant identification: the distinguishing features (threads, connection) are best visualized on a sharp, centered 2D image. The clinician always retains control: identification is a documented clinical decision, not an automated reading.

AI-Assisted Recognition

Manually identifying implants on 2D images is a use case where AI provides immediate time savings: it analyzes the implant’s morphological features on the X-ray and suggests the most likely compatible systems, which the practitioner then validates.

Spotimplant works on this principle: artificial intelligence-based dental implant recognition analyzes the X-ray and suggests a match in a matter of seconds, drawing from a database of implant systems. The dentist retains the final decision: AI assists the dentist; it does not replace them.

For a practice, the benefit is time savings and documented traceability; for a group of clinics, it is consistency in practices: regardless of which practitioner reviews the X-ray, the recommended course of action is the same, and the medical record is documented in the same way.

Record the information for traceability

Identification is only useful if the information is retained. The implant reference number, manufacturer, lot number, and date of implantation must be included in the patient’s medical record, ideally along with the annotated X-ray image. This is the key to stress-free maintenance and effective management of medical liability.

In Practice: Incorporating Identification into Your Protocol

Whether you’re handling an older case or standardizing practices across a group of clinics, the process is the same: a documented identification protocol, an accessible implant database, and a solution like Spotimplant integrated into the radiographic workflow. If you’d like to see how assisted identification fits into daily practice, request a demo: the Allisone team will show you how it works using your own X-rays.

Get the latest updates from Allisone your inbox.

Get the latest updates from Allisone your inbox.

Our best news, once a month.
Guaranteed spam-free and full of good advice!

Allisoneas the data controller, processes the personal data collected in this form in order to process your request. For more information, please consult our privacy policy
Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.

Not yet an Allisone user

Find out what Allisone can do for you

DISCOVER ALLISONE